본문 바로가기

카테고리 없음

Endress Hauser Dtm Files

The following products use the vulnerable HART DTM library and are affected:. Cerabar M / PMx 4x / V1.0. 1.2. Cerabar M 5x / PMx 5x / V1.00.xx. Cerabar S / PMx 7x / HART / FW 2.20.zz / Dev.Rev. 22.

Cerabar S / PMx 7x / V01.00. Cerabar S / PMx 7x / V02.00.

Cerabar S / PMx 7x / V02.10.xx. Cerabar S / PMx x3x / V1.x.

Cerabar S / PMx x3x / V2.x. Cerabar S / PMx x3x / V3.x. Cerabar S / PMx x3x / V5.0. Cerabar S / PMx x3x / V7.1.

Deltabar / FMD 7x / HART / FW 1.00.zz / Dev.Rev. 1. Deltabar M 5x / PMD 55 / V1.00.xx. Deltabar S / xMD 7x / HART / FW 2.20.zz / Dev.Rev.

22. Deltabar S / xMD 7x / V01.00. Deltabar S / xMD 7x / V02.00.

Deltabar S / xMD 7x / V02.10.xx. Deltabar S / xMD x3x / V1.x. Deltabar S / xMD x3x / V2.x. Deltabar S / xMD x3x / V5.0.

Deltabar S / xMD x3x / V7.1. Deltapilot M 5x / FMB 5x / V1.00.xx. Deltapilot S / DB 5x / V1.x. Deltapilot S / DB 5x / V2.0. Deltapilot S / FMB 70 / HART / FW 2.20.zz / Dev.Rev. 22. Deltapilot S / FMB 70 / V02.10.xx.

Gammapilot M / FMG 60 / HART / FW 1.04.zz / Dev.Rev. 3. Gammapilot M / FMG 60 / V01.xx. Gammapilot M / FMG 60 / V02.xx.

iTemp / TMT 122 / V1.1. iTemp / TMT 142 / V1.03.00. iTemp / TMT 162 / V1.00.00. 1.02.00. iTemp / TMT 162 / V1.03.00. iTemp / TMT 182 / V1.1. iTEMP / TMT82 / HART / FW 1.00.zz / Dev.Rev.

1. Levelflex / FMP 2xx / V2.0. 2.1. Levelflex M / FMP 40 / V2.00. Levelflex M / FMP 4x / V4.xx. Levelflex M Int / FMP 4x I / V1.08. Liquicap M / FMI 5x / 1.00.xx.

Liquicap M / FMI 5x / 1.03.xx. Liquiline Cond / CM 42 / HART / FW 2.01.zz / Dev.Rev. 1.

Liquiline M / CM44x / FW 1.02.zz / Dev.Rev. 1. Liquiline M Cci / CM 42 / HART / FW 13.06.zz / Dev.Rev. 10. Liquiline M Cci / CM 42 / HART / FW 13.07.zz / Dev.Rev.

11. Liquiline M Cci / CM 42 / V13.01.xx. Liquiline M Cci / CM 42 / V13.04.07.

Liquiline M Cci / CM 42 / V13.05.xx. Liquiline M DO / CM 42 / HART / FW 20.04.zz / Dev.Rev. 17.

Liquiline M DO / CM 42 / HART / FW 20.05.zz / Dev.Rev. 18. Liquiline M DO / CM 42 / V20.02.07. Liquiline M DO / CM 42 / V20.02.xx. Liquiline M DO / CM 42 / V20.03.xx. Liquiline M pH-ORP / CM 42 / HART / FW 10.06.zz / Dev.Rev. 0D.

Liquiline M pH-ORP / CM 42 / HART / FW 10.07.zz / Dev.Rev. 0E. Liquiline M pH-ORP / CM 42 / V10.02.xx.

Endress Hauser Devicecare

Liquiline M pH-ORP / CM 42 / V10.04.07. Liquiline M pH-ORP / CM 42 / V10.04.xx. Liquiline M pH-ORP / CM 42 / V10.05.xx.

Liquiline Oxygen / CM 42 / HART / FW 2.01.zz / Dev.Rev. 1.

Liquiline pHORP / CM 42 / HART / FW 2.01.zz / Dev.Rev. 1. Liquiport / CSPxx / HART / FW 01.02.zz / Dev.Rev.1.

Liquistation / CSFxx / HART / FW 01.02.zz / Dev.Rev.1. Liquisys M Chlorine / CCM 2x3 / V2.30. Liquisys M Chlorine / CCM 2x3 / V2.35. Liquisys M Cond. C / CLM 2x3 / V2.30. Liquisys M Cond. IMPROPER INPUT VALIDATIONSuccessful injection of specially crafted packets to the Device DTM causes a buffer overflow condition in the Frame Application.

The FDT Frame Application becomes unresponsive, and the Device DTM stops functioning.CVE-2014-9191 has been assigned to this vulnerability. A CVSS v2 base score of 1.8 has been assigned; the CVSS vector string is (AV:A/AC:H/Au:N/C:N/I:N/A:P). VULNERABILITY DETAILS EXPLOITABILITYThis exploit on the FDT/DTM Frame Application is possible from any adjacent network that receives or passes packets from the HART Device DTM. EXISTENCE OF EXPLOITNo known public exploits specifically target this vulnerability. DIFFICULTYThis is a complex vulnerability. Crafting a working exploit for this vulnerability would be difficult. Compromised access that allows access to the packets transmitted to Frame Application is required for exploitation.

This exploit also requires a specific timing to crash the Frame Application. This increases the difficulty of a successful exploit. MITIGATIONEndress+Hauser has released a security update addressing the HART Device DTMs. The update can be downloaded here:Endress+Hauser Inc. Technical supportTel.: 888-ENDRESSEndress+Hauser has recommended owners/operators to update HART DTM library 2.41 and FDT tool FieldCare to Version 2.10. For further information please consult the Release Notes and the Technical Information.ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of these vulnerabilities.

Specifically, users should:. Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls, and isolate them from the business network. When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize that VPN is only as secure as the connected devices.ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page at:.